Sylvania ToLEDo Ultra Output Platinum T8 G13 12W 1200mm – replaces 36W, 100k h
includes VAT 25.5% Shipping costs are calculated at checkout.
The Sylvania ToLEDo Ultra Output Platinum is a top-tier T8 LED tube designed to replace traditional 36W T8 fluorescent tubes. With a 100,000-hour lifespan and 201 lm/W efficiency, it is a reliable choice for offices, supermarkets, industrial facilities, and other demanding professional applications. Compatible with both magnetic ballasts (CCG) and direct 230V mains voltage.
T8 G13 base. CCG OR AC installation (requires a starter or rewiring depending on the installation method).
⚠ Order-based product
Delivery time is approximately 1 week from order. Availability can be checked in the shopping cart.
Technical specifications
- Replaces a traditional 36W T8 fluorescent tube
- Lamp type: T8 LED tube (CCG and AC compatible)
- Brand: Sylvania
- Series: ToLEDo Ultra Output Platinum
- Base: G13 (double-ended, T8 standard)
- Power: 12 W
- Luminous flux: 2,520 lm (4000K) / 2,350 lm (6500K)
- Color temperature: 4000 K or 6500 K (selectable)
- Luminous efficacy: 201 lm/W (industry-leading)
- Color Rendering Index (CRI): ≥ 80
- Lifespan: 100,000 hours
- Switching cycles: 200,000
- Compatibility: CCG (magnetic ballast) AND AC (direct 230V)
- Lamp construction: glass tube design, omnidirectional light distribution
- Warranty: 5 years
- Diameter: 28 mm
- Length: 1200 mm
- Product codes: 4000K = 0030251 / 6500K = 0030252
⚠️ MINIMUM ORDER FOR 6500K IS 10 PCS.
PURCHASES UNDER 10 PCS ARE POSSIBLE; PLEASE CONTACT CUSTOMER SERVICE.
Compatibility and installation
Dual compatibility — CCG and AC
This lamp operates in two different ways, offering greater installation flexibility:
Installation method 1: CCG (magnetic ballast)
- Suitable for older fluorescent fixtures with a magnetic ballast
- The starter must be replaced with an LED-compatible one (dummy S-starter)
- The magnetic ballast is left in place
- Simple direct replacement for the fluorescent tube
Installation method 2: AC (direct mains voltage)
- Suitable for new LED fixtures or renovation projects
- Ballast and starter are removed — requires rewiring
- The lamp is connected directly to 230V mains voltage
- Requires installation by a qualified electrician
Explore our selection in the Electrical Supplies → Ballasts/Control Gear category.
1200 mm length — 36W T8 fluorescent standard
This is a standard-sized 36W T8 fluorescent tube replacement, most commonly used in:
- Offices — general lighting in open offices, corridors, and meeting rooms
- Supermarkets and department stores — retail lighting in aisles and shelf areas
- Railway and service stations — general indoor lighting
- Parking lots and garages — long-life lighting
- Industrial facilities and warehouses — general lighting
- Hospitals and healthcare facilities — reliable lighting for long operating hours
Energy savings and total costs
A 12W LED produces the same light output as a 36W fluorescent tube but with significantly lower energy consumption:
- 36W T8 fluorescent tube: lifespan 12,000–24,000 h, requires multiple replacements over the years
- This 12W LED: lifespan 100,000 h — 4–8 times longer, no replacements needed
- Energy savings: approximately 67% (12W vs 36W)
- Lower heat emission — also reduces ventilation costs in hot environments
Glass tube design — omnidirectional light distribution
The glass tube design produces a 360° omnidirectional light distribution, just like a traditional T8 fluorescent tube. This differs from many LED tubes where light is directed in only one direction — providing more even light distribution in the space, fewer shadows, and suitability for reflector fixtures where light needs to reach the edges of the fixture.
EU EcoDesign regulations — fluorescent tube ban
The EU EcoDesign Directive 2019/2020 restricted the sale of T8 fluorescent tubes for new systems starting August 25, 2023. This LED alternative is fully compliant with EU regulations, acts as a direct replacement for fluorescent tubes using the CCG installation method, and is a long-term solution — the 100,000-hour lifespan makes it a future-proof choice.
Installation checklist
CCG installation (magnetic ballast):
- Check that the fixture is a T8 G13 base type and contains a magnetic ballast
- Turn off power at the main switch
- Remove the old fluorescent tube
- Replace the old starter with an LED-compatible one
- Install the new LED tube into the same holder
- Turn on the power and verify operation
AC installation (direct 230V):
- Qualified electrician required — requires rewiring
- Turn off power at the main switch
- The electrician removes the ballast and starter
- Wire directly to 230V mains voltage
- Install the LED tube
- Turn on the power and verify operation
Also check out our other T8 LED tubes.
Delivery
We ship your order from our warehouse in Jyväskylä. Orders placed before 2 PM are usually shipped on the same day. Free delivery within Finland for orders over €150.
Warranty
Products purchased through Lumenled come with a manufacturer's warranty, supported by Lumenled in cooperation with the importer. You can find detailed warranty terms here: Warranty terms of our partners.